{"product_id":"svf-set-set-to-produce-nanomize-tsvf","title":"SVF Set - Set to Produce \u0026 Nanomize tSVF","description":"\u003ch2\u003e\u003cspan\u003eA Specialized System for Mechanical Processing \u0026amp; Nanomization of Adipose Tissue\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSurgical Green SVF Set\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a specialized six-instrument system designed to support the sequential processing of harvested adipose tissue—from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emicrofat harvesting and transfer to mechanical fractionation, nanomization, and injection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system is designed around a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emechanical processing workflow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing specialized cannulas and transfer adapters for progressively processing adipose tissue into a finely fragmented tissue preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOne Set. Six Instruments. A Complete Mechanical Processing Workflow.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eHarvest → Transfer → Fractionate → Nanomize → Inject\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eDesigned for the tSVF Workflow\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Surgical Green SVF Set brings together six specialized instruments designed to support the principal stages of mechanical adipose-tissue processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e01 — INFILTRATE\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFacilitate distribution of tumescent solution at the harvesting site.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e02 — HARVEST\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEfficiently harvest adipose tissue, including from relatively fibrous tissue.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e03 — TRANSFER\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTransfer harvested adipose tissue between syringes under controlled conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e04 — FRACTIONATE\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMechanically process adipose tissue through a defined aperture to produce a finer tissue fraction.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e05 — NANOMIZE\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFurther process the tissue through a smaller aperture to achieve a finer preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e06 — INJECT\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePrecisely deliver the resulting preparation using a fine blunt-tip injector.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eSix Specialized Instruments\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003e#\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eInstrument\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSize \/ Specification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003ePrimary Function\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e01\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInfiltration Cannula\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm \/ 14G × 30 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTumescent infiltration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e02\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAggressive Multiport Harvester – Both-End Sharp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 mm \/ 13G × 20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdipose-tissue harvesting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e03\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAnaerobic Transfer Adapter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.4 mm internal aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransfer of adipose tissue between syringes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e04\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAnaerobic Fractionation Adapter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 mm internal aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical fractionation of adipose tissue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e05\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAnaerobic Nanomization Adapter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 mm internal aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFurther mechanical processing \/ nanomization\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e06\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlunt-Tip Injector – Straight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 mm \/ 19G × 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInjection of processed tissue preparation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003e01 — Infiltration Cannula\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for Tumescent Infiltration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2.0 mm Infiltration Cannula\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e features \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20 holes of 2.0 mm diameter arranged across four spiral rows\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe multiport configuration is designed to facilitate distribution of tumescent solution across the harvesting area.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eDiameter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.0 mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGauge:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 14G\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30 cm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePort configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 20 × 2.0 mm holes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eArrangement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4 spiral rows\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003e02 — Aggressive Multiport Harvester\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eBoth-End Sharp\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eDesigned for Efficient Adipose-Tissue Harvesting\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2.5 mm Both-End Sharp Harvester\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e features small ports with sharp edges designed to facilitate adipose-tissue harvesting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 2.0 mm ports and both-end sharp configuration provide a specialized harvesting geometry for efficient tissue collection, including applications involving relatively fibrous tissue.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eDiameter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.5 mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGauge:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 13G\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 20 cm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePort diameter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.0 mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eConfiguration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Both-end sharp\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003e03 — Anaerobic Transfer Adapter\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eControlled Tissue Transfer\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAnaerobic Transfer Adapter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2.4 mm internal aperture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is designed to facilitate transfer of harvested adipose tissue from one syringe to another under controlled conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts purpose within the system is to provide a dedicated transfer stage before further mechanical processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInternal aperture:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.4 mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Adipose-tissue transfer\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Syringe-to-syringe transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003e04 — Anaerobic Fractionation Adapter\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eMechanical Adipose-Tissue Fractionation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAnaerobic Fractionation Adapter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1.2 mm internal aperture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is designed for mechanical processing of harvested adipose tissue into a finer tissue fraction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis forms the fractionation stage of the Surgical Green mechanical processing workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInternal aperture:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1.2 mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mechanical fractionation\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Adipose-tissue processing\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003e05 — Anaerobic Nanomization Adapter\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eFurther Mechanical Tissue Processing\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAnaerobic Nanomization Adapter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.9 mm internal aperture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is designed for further mechanical processing following the fractionation stage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe smaller aperture provides the next stage in the progressive mechanical reduction of the processed adipose tissue.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInternal aperture:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.9 mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mechanical nanomization\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Further processing following fractionation\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003e06 — Blunt-Tip Injector\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eStraight\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eFine, Controlled Injection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.9 mm Straight Blunt-Tip Injector\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to facilitate controlled injection of the resulting processed tissue preparation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts fine diameter and blunt tip provide a configuration intended for applications requiring precise cannula positioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eDiameter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.9 mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGauge:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 19G\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 5 cm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eConfiguration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Straight\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eTip:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Blunt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Surgical-green","offers":[{"title":"Default Title","offer_id":59486070571353,"sku":null,"price":250.0,"currency_code":"GBP","in_stock":true}],"url":"https:\/\/www.surgicalgreen.com\/products\/svf-set-set-to-produce-nanomize-tsvf","provider":"Surgical-green","version":"1.0","type":"link"}