Skip to product information
1 of 3

Mesh for Nano Filter - Reusable set of 10

Mesh for Nano Filter - Reusable set of 10

Regular price £50.00
Regular price Sale price £50.00
Sold out
Tax included. Shipping calculated at checkout.

Surgical Green’s Mesh for Nano Filter is a reusable set of 10 stainless-steel mesh components designed to separate larger adipose-tissue fractions from smaller fat-cell fractions during Nano Filter processing. Standard mesh size is #40/400 microns, with #60/600-micron and #80/800-micron sizes available on demand. The non-magnetic mesh is ultrasonically cleaned, latex-free, non-sterile, individually packed, tested, and quality-control passed.

Size
View full product details

Surgical Green Mesh for Nano Filter – Reusable Set of 10

Surgical Green Mesh for Nano Filter is a reusable set of 10 non-magnetic stainless-steel mesh components designed for use with the Surgical Green Nano Filter. The mesh supports separation of larger adipose-tissue fractions from smaller fat-cell fractions during a professional nano-fat processing workflow.

The standard mesh specification is #40 or 400 microns. Additional #60 or 600-micron and #80 or 800-micron sizes are available on demand, allowing the required mesh grade to be selected for the intended processing protocol.

This listing is for a reusable set of 10 mesh components. The Nano Filter unit, syringes, cannulas, connectors, and other processing accessories are not stated as included.

Size-Selective Adipose-Tissue Filtration

The mesh is designed to retain larger adipose-tissue fractions while permitting smaller fractions to progress through the Nano Filter workflow. Mesh selection affects the physical separation stage, so the required micron size should be confirmed against the intended protocol before ordering or use.

The product description identifies #40/400 microns as the standard option. The #60/600-micron and #80/800-micron versions are supplied on demand rather than described as standard stock.

Reusable Set for Nano Filter Workflows

Each product set contains 10 reusable mesh components. The set format supports procedural inventory planning and replacement scheduling in facilities that use the Surgical Green Nano Filter.

Compatibility is stated with the Surgical Green Nano Filter. Compatibility with other filtering systems, housings, or accessories is not supplied and should be confirmed before purchase.

High-Quality Manufacturing

The mesh is manufactured from non-magnetic stainless steel and is ultrasonically cleaned. The technical specification states that it is not dull-polished. It is reusable, Premium OR grade, latex-free, non-sterile, individually packed, and quality-control passed.

The supplied information lists a Boil Test, Bioburden Test, and Residual Test. Because the mesh is supplied non-sterile, it must be inspected, cleaned, and sterilized according to validated manufacturer instructions and the healthcare facility’s protocols before use.

Why Choose Surgical Green Mesh for Nano Filter

Feature

Added Benefit

Reusable set of 10

Supports procedural inventory planning and repeat professional use after validated reprocessing.

Designed for the Surgical Green Nano Filter

Provides the stated compatibility for the intended adipose-tissue filtering workflow.

Standard #40/400-micron mesh

Provides the standard size specified for separating larger and smaller tissue fractions.

#60/600-micron option on demand

Offers an alternative mesh size when required by the selected protocol.

#80/800-micron option on demand

Provides an additional on-demand size for protocol-specific selection.

Non-magnetic stainless steel

Provides the specified reusable material for professional processing equipment.

Ultrasonically cleaned

Confirms completion of the stated manufacturing-cleaning step.

Latex-free

Supports facilities where latex status is an important purchasing requirement.

Boil, bioburden, and residual tested

Confirms completion of the three tests stated in the supplied product data.

Individually packed and QC passed

Supports organized receipt and confirms the stated quality-control status.

 

Professional-use notice: This non-sterile, reusable mesh set is intended for appropriately trained and qualified healthcare professionals. Confirm the required mesh size, Nano Filter compatibility, complete system components, validated cleaning and sterilization instructions, inspection requirements, tissue-processing protocol, and facility procedures before use. Processing performance depends on correct selection, installation, handling, reprocessing, and professional technique.

Product name

Mesh for Nano Filter – Reusable Set of 10

Brand

Surgical Green

Product type

Reusable mesh components for the Surgical Green Nano Filter

Set quantity

10 mesh components

Primary function

Separating larger adipose-tissue fractions from smaller fat-cell fractions

Standard size

#40 or 400 microns

On-demand size

#60 or 600 microns

Additional on-demand size

#80 or 800 microns

Material

Non-magnetic stainless steel

Ultrasonically cleaned

Yes

Dull-polished

No

Reusable

Yes

Grade

Premium OR

Latex status

Latex-free

Sterility

Non-sterile

Tests performed

Boil Test, Bioburden Test, and Residual Test

Packing

Individually packed; confirm whether this applies to each mesh or the full set

Quality control

QC passed

Included accessories

Nano Filter unit, syringes, cannulas, connectors, and other accessories are not stated as included

What is Mesh for Nano Filter used for?

It is designed to separate larger adipose-tissue fractions from smaller fat-cell fractions during processing through the Surgical Green Nano Filter.

How many mesh components are included?

The product title specifies a reusable set of 10 mesh components.

What is the standard mesh size?

The standard specification is #40 or 400 microns.

Are other mesh sizes available?

Yes. The supplied information states that #60 or 600-micron and #80 or 800-micron sizes are available on demand.

Does the mesh size affect filtration?

Mesh size affects the physical separation stage. Confirm the required micron size against the intended tissue-processing protocol before ordering or use.

Is the Nano Filter unit included?

No Nano Filter unit is stated as included. This listing is specifically for the reusable mesh set.

Are syringes, cannulas, or connectors included?

The supplied workbook does not state that syringes, cannulas, connectors, or other accessories are included.

Is the mesh compatible with other filtering systems?

Compatibility is stated with the Surgical Green Nano Filter. Compatibility with other systems is not supplied and should be confirmed before purchase.

What material is the mesh made from?

The mesh is manufactured from non-magnetic stainless steel.

Is the mesh reusable?

Yes. It is identified as reusable and must be inspected, cleaned, and sterilized according to validated manufacturer instructions before reuse.

Is the mesh supplied sterile?

No. The technical specifications identify the mesh as non-sterile. It must be prepared according to validated instructions before clinical use.

Is the product latex-free?

Yes. The supplied technical specifications identify the mesh as latex-free.

Has the mesh been ultrasonically cleaned?

Yes. The supplied product data states that it has been ultrasonically cleaned.

Is the mesh dull-polished?

No. The supplied technical specification explicitly states that the mesh is not dull-polished.

What tests have been performed?

The supplied data lists a Boil Test, Bioburden Test, and Residual Test.

How is the mesh packed?

The supplied specification states that it is individually packed. Confirm whether the packing statement applies to each mesh or the complete set if this matters to procurement.

Has the product passed quality control?

Yes. The supplied specification states that quality control has been passed.

Who should use the Nano Filter Mesh set?

The mesh set is intended for appropriately trained and qualified healthcare professionals familiar with adipose-tissue processing, mesh selection, system assembly, reprocessing, and the applicable clinical protocol.