The Surgical Green Single-Use 6-Port Spiral Cannula is designed for professional multi-plane adipose-tissue harvesting. The supplied workbook positions it for small-volume procedures, including appropriate cases performed under local anesthesia.
Six openings are arranged in a spiral orientation to distribute suction around the working end. Available lengths range from 15 cm to 35 cm for different access depths, while multiple connection options allow the appropriate aspiration-system interface to be selected.
The six-port pattern distributes openings around the cannula rather than placing them in a single line. This arrangement is intended to support access across multiple tissue planes as the cannula is positioned and moved according to the harvesting protocol.
The source describes uniform suction but does not provide flow testing, port dimensions, suction pressure, or comparative performance data. Actual suction depends on cannula diameter, port geometry, tubing or syringe connection, aspiration pressure, tissue, and professional technique.
The supplied description identifies the 6-Port Spiral Cannula as a commonly selected option for small-volume harvesting procedures performed under local anesthesia. The cannula itself does not determine anesthetic suitability, procedural setting, harvest volume, or patient eligibility.
Anesthesia selection, monitoring, treatment area, harvested volume, and operative protocol remain clinical decisions for the qualified healthcare team. No safety, efficacy, tissue-viability, or patient-outcome claim is guaranteed by the provided product information.
Available lengths span 15 cm to 35 cm, supporting selection for different access-depth requirements. The exact intermediate lengths are not listed and should be confirmed before ordering.
Multiple connection options are available to support firm attachment, but connector standards and compatible syringes, handles, tubing, or suction systems are not stated. Confirm the selected connection and full aspiration-system compatibility before use.
This product is designated for single use and should not be cleaned, sterilized, reprocessed, or reused after the procedure unless authorized manufacturer labeling explicitly states otherwise. Single-use designation does not by itself establish sterile supply.
The supplied workbook does not identify material, diameter, wall thickness, distal-tip geometry, port dimensions, finish, sterility, latex status, packaging, testing, quality-control status, or regulatory classification. Confirm these details from approved product specifications or labeling before purchase or clinical use.
|
Feature |
Added Benefit |
|
Six-port pattern |
Provides six openings for distributed adipose-tissue aspiration. |
|
Spiral port orientation |
Positions the openings around the working end for circumferential access. |
|
Multi-plane harvesting design |
Supports professional harvesting across selected tissue planes when used with appropriate technique. |
|
Distributed suction positioning |
Designed to support suction around the cannula when system settings and movement are appropriate. |
|
Small-volume procedure focus |
Positioned for appropriate limited-volume harvesting workflows. |
|
Local-anesthesia workflow reference |
May be selected in procedures conducted under local anesthesia when clinically determined. |
|
15–35 cm length range |
Provides length selection for different access-depth requirements. |
|
Multiple connection options |
Supports selection of the interface required for the intended aspiration system. |
|
Single-use designation |
Requires disposal after one procedure and avoids reuse of the same cannula across cases. |
Professional-use notice: This single-use harvesting cannula is intended for appropriately trained and qualified healthcare professionals. Confirm material, exact length, diameter, distal-tip and port geometry, connection type, compatible aspiration system, sterility, package integrity, intended-use labeling, tissue plane, anesthesia plan, pressure requirements, disposal instructions, and procedure-specific protocols before use. Do not reuse. No uniform-flow, safety, efficacy, tissue-viability, harvest-volume, or clinical-outcome guarantee is made.
|
Product name |
Single Use – 6 Spiral Port Cannula |
|
Recommended SEO name |
Single-Use 6-Port Spiral Harvesting Cannula |
|
Brand |
Surgical Green |
|
Product type |
Single-use adipose-tissue harvesting cannula |
|
Primary application |
Multi-plane adipose-tissue harvesting |
|
Port count |
Six ports |
|
Port orientation |
Spiral |
|
Suction positioning |
Distributed suction around the working end; uniformity is not independently quantified |
|
Procedure-volume positioning |
Small-volume procedures |
|
Anesthesia context referenced |
Local anesthesia; clinical suitability must be determined independently |
|
Length range |
15 cm to 35 cm |
|
Intermediate length options |
Not listed in the supplied workbook; confirm before ordering |
|
Connection options |
Multiple options available; exact connector standards are not stated |
|
Use cycle |
Single use; do not reprocess or reuse |
|
Material |
Not stated in the supplied workbook |
|
Cannula diameter |
Not stated in the supplied workbook |
|
Distal-tip and port dimensions |
Not stated in the supplied workbook |
|
Syringe, handle, tubing, or suction compatibility |
Not stated; confirm the selected connector and system |
|
Sterility |
Not stated in the supplied workbook; single-use does not automatically mean sterile |
|
Latex status |
Not stated in the supplied workbook |
|
Packaging and quantity |
Not stated in the supplied workbook |
|
Tests and quality control |
Not stated in the supplied workbook |
|
Regulatory classification |
Not stated in the supplied workbook |