The Surgical Green Single-Use Three-Port Basket Cannula is designed for professional equalizing, fat-injection, and suction workflows. It is positioned for areas with skin irregularities and for procedures involving reinjection of larger adipose-tissue volumes, including appropriate buttock fat-transfer applications.
Three openings are arranged in a spiral orientation to support circumferential 360-degree suction coverage. Available lengths range from 15 cm to 35 cm for different access depths, while multiple connection options allow the correct system interface to be selected.
The three-port basket pattern distributes openings around the working end rather than placing them in a single line. This arrangement is intended to provide circumferential access during suction or tissue distribution when the cannula is positioned and moved according to the procedure.
The supplied workbook describes uniform 360-degree suction but does not provide flow testing, port dimensions, or comparative performance data. Actual suction and distribution depend on cannula diameter, port geometry, tubing or syringe connection, pressure, tissue, and professional technique.
The source positions the Basket Cannula as an equalizer, injector, and suction cannula. This multifunctional role supports selection for contour-management workflows, fat delivery, or aspiration when the chosen dimensions and connector are appropriate for the intended task.
The workbook also references larger-volume adipose-tissue reinjection, particularly in the buttock region. It does not define an allowable volume, procedural technique, tissue plane, diameter, or clinical indication, so these requirements must be determined by the qualified surgeon and applicable protocol.
Available lengths span 15 cm to 35 cm, supporting selection for different access depths. The exact intermediate lengths are not listed and should be confirmed before ordering.
Multiple connection options are available to support firm attachment, but the connector standards and compatible syringes, handles, tubing, or suction systems are not stated. Confirm the selected connection and full system compatibility before use.
This product is designated for single use and should not be cleaned, sterilized, reprocessed, or reused after the procedure unless authorized manufacturer labeling explicitly states otherwise. Single-use designation does not by itself establish sterile supply.
The supplied workbook does not identify material, diameter, wall thickness, detailed tip geometry, finish, sterility, latex status, packaging, testing, quality-control status, or regulatory classification. These details should be confirmed from the approved product specification or labeling before purchase or clinical use.
|
Feature |
Added Benefit |
|
Three-port basket pattern |
Provides three openings for suction or tissue-delivery workflow selection. |
|
Spiral hole orientation |
Distributes openings around the working end for circumferential access. |
|
360-degree suction positioning |
Designed to support suction coverage around the cannula when technique and system settings are appropriate. |
|
Equalizer function |
Supports professional contour-management workflows in areas with skin irregularities. |
|
Injection function |
Supports delivery of prepared adipose tissue when the chosen size and connection are compatible. |
|
Suction function |
Supports aspiration when connected to an appropriate syringe or suction system. |
|
15–35 cm length range |
Provides length selection for different access-depth requirements. |
|
Multiple connection options |
Supports selection of the interface required for the intended system. |
|
Large-volume positioning |
Designed for workflows involving larger fat-reinjection volumes when clinically appropriate. |
|
Single-use designation |
Requires disposal after one procedure and avoids reuse of the same cannula across cases. |
Professional-use notice: This single-use basket cannula is intended for appropriately trained and qualified healthcare professionals. Confirm material, exact length, diameter, tip and port geometry, connection type, compatible syringe or suction system, sterility, package integrity, intended-use labeling, tissue plane, volume requirements, disposal instructions, and procedure-specific protocols before use. Do not reuse. No uniform-flow, skin-correction, tissue-trauma, contouring, graft-survival, or clinical-outcome guarantee is made.
|
Product name |
Single Use – Basket Cannula |
|
Recommended SEO name |
Single-Use Three-Port Basket Cannula |
|
Brand |
Surgical Green |
|
Product type |
Single-use multifunctional basket cannula |
|
Stated functions |
Equalizer, injector, and suction cannula |
|
Port count |
Three ports |
|
Port orientation |
Spiral orientation for circumferential 360-degree suction positioning |
|
Length range |
15 cm to 35 cm |
|
Intermediate length options |
Not listed in the supplied workbook; confirm before ordering |
|
Connection options |
Multiple options available; exact connector standards are not stated |
|
Stated workflow |
Areas with skin irregularities and larger-volume adipose-tissue reinjection |
|
Anatomical area referenced |
Buttocks, when clinically appropriate |
|
Use cycle |
Single use; do not reprocess or reuse |
|
Material |
Not stated in the supplied workbook |
|
Cannula diameter |
Not stated in the supplied workbook |
|
Detailed tip and port dimensions |
Not stated in the supplied workbook |
|
Syringe, handle, tubing, or suction compatibility |
Not stated; confirm the selected connector and system |
|
Sterility |
Not stated in the supplied workbook; single-use does not automatically mean sterile |
|
Latex status |
Not stated in the supplied workbook |
|
Packaging and quantity |
Not stated in the supplied workbook |
|
Tests and quality control |
Not stated in the supplied workbook |
|
Regulatory classification |
Not stated in the supplied workbook |